A structural audit combines a visual survey with non-destructive tests (NDT) that measure the strength and condition of concrete and steel without damaging the building. The common tests are rebound hammer, ultrasonic pulse velocity, core cutting, cover meter, carbonation depth and half-cell potential.
The common tests
- Rebound hammer: a spring-loaded hammer measures surface hardness, which gives an indication of concrete strength. Quick, and good for comparing many members.
- Ultrasonic pulse velocity (UPV): measures how fast a sound pulse travels through concrete. Slower pulses point to cracks, voids or poor-quality concrete.
- Core test: a small cylinder is cut from the concrete and crushed in a lab. The most reliable strength measure, used to calibrate the other tests.
- Cover meter: finds the steel bars and measures the concrete cover over them. Thin cover lets corrosion start sooner.
- Carbonation depth: a chemical indicator shows how deep carbon dioxide has entered the concrete. Once it reaches the steel, the steel can start to rust.
- Half-cell potential: measures the electrical potential of the steel to estimate where corrosion is likely.
How an audit is done
- Study the drawings and the building's history: age, alterations, leakage.
- Visual survey of cracks, spalling, exposed or rusted steel, dampness and deflection.
- NDT at selected locations, chosen from the survey.
- Analysis of results against the loads the building carries.
- A report grading the building's condition, with repair or strengthening advice and its urgency.
When you need one
Older buildings, visible cracks or leakage, a change of use or extra floors, and many municipal and society requirements for periodic audits. Try our building health self-check first.